Nfpa 101 Chapter 7 Means Of Egress

Nfpa 101 Chapter 7 Means Of EgressChapter 7 According to NFPA 101, what is the minimum clear width of the opening for: Single Doors Pairs of Doors 32" At least one of the doors 32" List the three separate. After the means of egress is determined, it is the necessary to define the lighting requirements. Chapter 7 Means of Egress 7. NFPA 101, 2018 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5. Sizing is accomplished by. 0 (1 review) A means of egress is composed of what 3 basics elements: Click the card to flip 👆 1) The exit access 2) The exit 3) The exit discharge Click the card to flip 👆 1 / 53 Flashcards Learn Test Match Created by ramseyc19 Terms in this set (53). NFPA 101 : 2021 Current Add to Watchlist Life Safety Code Available format (s): Hardcopy Language (s): English Published date: 08-21-2020 Publisher: National Fire Protection Association Table of Contents Abstract General Product Information Standards Referenced By This Book Categories associated with this Standard. 8; while emergency lighting only must comply where one of the criteria is true: The building is over 3 stories tall. The means of egress protection requirements work in coordination with other sections of the code, such as protection of vertical openings (see Chapter 7), interior finish (see Chapter 8), fire suppression and detection systems (see Chapter 9) and numerous others, all having an impact on life safety. Referenced in this blog are design requirements for exits, exit accesses and exit discharge paths. The text is needed in NFPA 101 to avoid a conflict between Chapter 7 and Chapter 42. NFPA 101, Life Safety Code, Chapter 7 Means of Egress 7. Chapter 7, Means of Egress, Fire Inspection and Code Enforcement 8th edition 5. Means of egress from dwelling units to the outside of the building are in accordance with Chapter 7, and the means of egress is continuously maintained free of all obstructions to full instant use in case of emergency. (Where you have other than standard stairs such as. Ensure there's a safe way out of every structure! The 2002 edition of NFPA 101B has been updated to reflect the egress requirements of the 2000 edition of NFPA 101®: Life Safety Code®. For example, NFPA 101 Section 7. The means of egress shall have a ceiling height of not less than 7 feet 6 inches (2286 mm). Chapter 7 Means of Egress 7. Sloped ceilings in accordance with Section 1208. 9 Emergency Lighting 7. 8 Means of Egress General. 7. NFPA 101 Chapter 31 Existing apartment buildings Apartment buildings are considered to be “existing” if they were occupied prior to the adoption of the Life Safety Code edition currently in force. In buildings that are fully sprinklered. (Where you have other than standard stairs such as curved stairs, spiral stairs or winders within a means of egress, consult NFPA 101, Life Safety Code, Chapter 7 for further details on their design. Chapter 7 Means of Egress Chapter 8 Features of Fire Protection Chapter 9 Building Service and Fire Protection Equipment Chapter 10 Interior Finish, Contents, and. 1 indicates that egress shall be arranged such that each occupant has access to not less than two means of egress. ” NFPA 101 Chapters 7-11 all apply to both new and existing buildings, so you’ll need to review these chapters for specific existing building requirements that could apply to your situation. 8* The requirements of this chapter shall apply based on the assumption that staff is. The locking means shall be capable of being engaged without opening the door. The egress window is required when the building lacks an. Means of escape within a resident room or resident dwelling unit complies with 24. NFPA 101, 2021 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5 Performance-Based Option Chapter 6 Classification of Occupancy and Hazard of Contents Chapter 7 Means of Egress Chapter 8 Features of Fire Protection. NFPA 101 Egress Doors Door-locking arrangements shall be permitted where patient special needs require specialized protective measures for their safety, provided that all of the following criteria are met: (1) Staff can readily unlock doors at all times in accordance with 20. NFPA® offers this document as a comprehensive substitute for the means of egress chapters of other organizations' building codes. These standard stair design details are mandated for egress stairs in the exit access, exits and exit discharge. Means of egress design must consider the distance occupants travel to an exit, how far apart exits are located from one another, and the arrangement of the. The Code requirements for accessible means of egress are in agreement with those of the Americans with Disabilities Act Accessibility Guidelines for Buildings and Facilities (ADAAG); its successor, the ADA and ABA Accessibility Guidelines for Buildings and Facilities (ADA-ABA-AG); and ICC/ANSI A117. Ensure there's a safe way out of every structure! The 2002 edition of NFPA 101B has been updated to reflect the egress requirements of the 2000 edition of NFPA 101®: Life Safety Code®. Access-controlled egress (18/19. Chapter 7 According to NFPA 101, what is the minimum clear width of the opening for: Single Doors Pairs of Doors 32" At least one of the doors 32" List the three separate parts of the Means of Egress exit access exit exit discharge At what occupancy level is a door required to swing in the direction of egress? 50 Door and Hardware Institute. The egress requirements in NFPA 101 shall be used in lieu of the egress requirements in the International Building Code. The means of egress protection requirements work in coordination with other sections of the code, such as protection of vertical openings (see Chapter 7), interior finish (see Chapter 8), fire suppression and detection systems (see Chapter 9) and numerous others, all having an impact on life safety. Maine adopted the 2018 edition of NFPA 101 on November 1, 2019. The currently adopted edition is the 2018 edition. NFPA 101 has an extensive amount of information and requirements for stairs and stair enclosures. NFPA 101 The Life Safety Code, is the State adopted code for the protection of life in buildings. Means of escape within a resident room or resident dwelling unit complies with 24. The Code requirements for accessible means of egress are in agreement with those of the Americans with Disabilities Act Accessibility Guidelines for Buildings and Facilities (ADAAG); its successor, the ADA and ABA Accessibility Guidelines for Buildings and Facilities (ADA-ABA-AG); and ICC/ANSI A117. NFPA 101, Life Safety Code, shall be known as the Life Safety Code®, is cited as such, and shall be referred to herein as “this Code” or “the Code. (760 mm) above the floor or the finished ground level below except where guards are specifically exempted by provisions of Chapters 11 through 43. Access-controlled egress door assemblies as defined in NFPA 101-2012: 7. A business occupancy we're working on has 550 occupants, and requires three means of egress per Section 7. NFPA 101 ®, Life Safety Code ®, is referenced by countless industries, organizations, departments, and professionals across North America and around the world to help. The Life Safety Code applies to both new and existingbuildings. Access-controlled egress (18/19. NFPA 101B presents egress provisions for use as part of a building code and not as a stand-alone document. 2) _____ Submitter: Technical Committee Means of Egress Recommendation: 7. Means of Egress: A continuous and unobstructed path of travel from any point in a building or structure to a public way that consists of the following three separate and distinct parts: Exit access: The travel path or area that leads from where a person is located to the entrance to an exit. Chapter 7, Means of Egress, Fire Inspection and Code Enforcement 8th edition 5. Means of Egress: A continuous and unobstructed path of travel from any point in a building or structure to a public way that consists of the following three separate and distinct parts: Exit access: The travel path or area that leads from where a person is located to the entrance to an exit. Emergency lighting illuminates the means of egress which includes stairs, aisles, corridors, ramps, and escalators leading to an exit. Emergency lighting illuminates the means of egress which includes stairs, aisles, corridors, ramps, and escalators leading to an exit. The 2003 NFPA 101: Life Safety Codeis a complete safety system that includes rules for the full range of occupancies; egress requirements, stair markings, and emergency lighting; provisions concerning features of fire protection; and a sophisticated performance-based option for code compliance. 1, American National Standard for Accessible and …. 8 Means of Egress General. 1 states “Means of egress for both new and existing buildings shall comply with this chapter. Where approved by the authority having jurisdiction, outside stairs shall be permitted to lead to roofs of other sections of a building or an adjoining building where the construction is fire resistive and there is a continuous and safe means of egress from the roof. Means of egress shall be continuously maintained free of all obstructions or impediments to full instant us e in the case of fire or other emergency. Chapter 7, Means of Egress, Fire Inspection and Code Enforcement 8th edition 5. NFPA 101 The Life Safety Code, is the State adopted code for the protection of life in buildings. 1, American National Standard for Accessible and. NFPA 101: Why There is a Life Safety Code Minimizing the danger to life by fire and providing suitable means of egress are logical ways of granting life safety to building occupants, but they haven’t. Means of egress design must consider the distance occupants travel to an exit, how far apart exits are located from one another, and the arrangement of the paths of travel within the means of egress. NFPA 101 Chapter 31 Existing apartment buildings Apartment buildings are considered to be “existing” if they were occupied prior to the adoption of the Life Safety. Means of egress design must consider the distance occupants travel to an exit, how far apart exits are located from one another, and the arrangement of the paths of travel within the means of egress. Egress shall require not more than one releasing operation. NFPA 101, 2018 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5 Performance-Based Option Chapter 6 Classification of Occupancy and Hazard of Contents Chapter 7 Means of Egress Chapter 8 Features of Fire Protection. NFPA 101B presents egress provisions for use as part of a building code and not as a stand-alone document. The criteria of Chapter 7 was expanded to have applica-bility to all three portions of the means of egress: exit access, exit, and exit discharge. Means of egress design must consider the distance occupants travel to an exit, how far apart exits are located from one another, and the arrangement of the paths of travel within the means of egress. 1 Emergency lighting facilities for means of egress shall be provided in accordance with Section 7. Chapter 7 Means of Egress 7. The contents of NFPA 101B reflect the up-to-date expertise of the requirements. The Code requirements for accessible means of egress are in agreement with those of the Americans with Disabilities Act Accessibility Guidelines for Buildings and Facilities (ADAAG); its successor, the ADA and ABA Accessibility Guidelines for Buildings and Facilities (ADA-ABA-AG); and ICC/ANSI A117. Egress lighting must fully comply with §7. 2 Vehicle ramps in parking structures, as permitted in 42. The fire stairs headroom is defined under NFPA 101 Chapter 7 Means of Egress section 7. Emergency lighting is key in making sure people can exit a building safely in the event of an emergency. ith the new edition of NFPA 101, Life Safety Code, the 2009 edition adds provisions to Chapter 7 for electrically controlled egress doors, horizontal-sliding doors, elevator lobby access door locking, and door inspection and maintenance. The criteria of Chapter 7 was expanded to have applica-bility to all three portions of the means of egress:. It is a basic concept of the Code that the means of egress system be sized to accommodate all people occupying a building. NFPA 101B presents egress provisions for use as part of a building code and not as a stand-alone document. NFPA 101 : 2021 Current Add to Watchlist Life Safety Code Available format (s): Hardcopy Language (s): English Published date: 08-21-2020 Publisher: National Fire Protection Association Table of Contents Abstract General Product Information Standards Referenced By This Book Categories associated with this Standard. Chapter 7: Means of Egress, Georgia Life Safety Code 2018 | UpCodes CODES Georgia Life Safety Code 2018 Adopts With Amendments: NFPA 101, 2018 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5 Performance-Based Option. Upon completion, you should be able to: Explain classifications of occupancy, including NFPA 101 requirements relevant to new and existing buildings Reference provisions for components of the building's means of egress, fire alarm and suppression systems, and other fire protection features. 0 (1 review) A means of egress is composed of what 3 basics elements: Click the card to flip 👆 1) The exit access 2) The exit 3) The exit discharge Click the card to flip 👆 1 / 53 Flashcards Learn Test Match Created by ramseyc19 Terms in this set (53). (Where you have other than standard stairs such as curved stairs, spiral stairs or winders within a means of egress, consult NFPA 101, Life Safety Code, Chapter 7 for further details on their design. The purpose of the egress window is to provide an occupant with an alternate escape route when fire or smoke blocks the primary means of escape from the dwelling unit. Ceilings of dwelling units and sleeping units within residential occupancies in accordance with Section 1208. Access-controlled egress door assemblies as defined in NFPA 101-2012: 7. The 2002 edition of NFPA 101B has been updated to reflect the egress requirements of the 2000 edition of NFPA 101®: Life Safety Code®. NFPA 101 part of the 2020 FFPC, 7 th edition Adopts With Amendments: NFPA 101, 2018 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5 Performance-Based Option Chapter 6 Classification of Occupancy and Hazard of Contents Chapter 7 Means of Egress 7. Mixing and matching of these features is not compliant. 6, and not on an accessible means of egress or other accessible element shall be exempt from the provisions of 7. Components of Egress Exit Access-Portion of a means of egressthat leads to an exit Exit- Area separated from all other spacesby construction or equipment to protectway of travel to the discharge Exit Discharge-Area between thetermination of the. 3, the means of egress illumination level shall be provided at not less than 1 footcandle (11 lux) at the walking surface. The NFPA 101, Life Safety Code Handbook features complete Code text along with expert commentary that provides a narrative interpretation designed to make it easier to comprehend and apply provisions and. 2 (NFPA 101, 2018 Edition). The Life Safety Code was first adopted in Maine in 1959. NFPA 101 Chapter 31 Existing apartment buildings Apartment buildings are considered to be "existing" if they were occupied prior to the adoption of the Life Safety Code edition currently in force. NFPA 101, 2018 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5 Performance-Based Option Chapter 6 Classification of Occupancy and Hazard of Contents Chapter 7 Means of Egress Chapter 8 Features of Fire Protection. The criteria of Chapter 7 was expanded to have applica-bility to all three portions of the means of egress:. Means of Egress: A continuous and unobstructed path of travel from any point in a building or structure to a public way that consists of the following three separate and distinct. Emergency lighting is key in making sure people can exit a building safely in the event of an emergency. 1 indicates that egress shall be arranged such that each occupant has access to not less than two means of egress. For example, NFPA 101 Section 7. The NFPA 101, Life Safety Code Handbook features complete Code text along with expert commentary that provides a narrative interpretation designed to make it easier to comprehend and apply provisions and explain technical language to nontechnical people. Any door assembly in a means of egress shall be of the side-hinged or pivoted-swinging type, and shall be installed to be capable of swinging from any position to the full required width of the opening in which it is installed, unless otherwise specified as follows: (1) Door assemblies in dwelling units, as provided in Chapter 24, shall be …. Ensure there's a safe way out of every structure! The 2002. These standard stair design details are mandated for egress stairs in the exit access, exits and exit discharge. 2) Access-controlled locking arrangements involve electronically locked doors that restrict egress. These standard stair design details are mandated for egress stairs in the exit access, exits and exit discharge. Local jurisdictions may have previous (or newer) editions of NFPA 101 adopted. 3 will allow doors not in a required means of egress to be locked in new and existing health care occupancies. 5 and may result in the addition of exterior drains if the landscape cannot allow for natural drainage. After the means of egress is determined, it is the necessary to define the lighting requirements. 1* Application Means of egressfor both new and existing buildingsshall comply with this chapter. The requirements below supersede the requirements of the NFPA 101: In buildings that are fully sprinklered, 1-hour fire rated corridors shall not be required. 1, as well as NFPA 101 7. The egress requirements in NFPA 101 shall be used in lieu of the egress requirements in the International Building Code. pps from FSE 101 at Eastern Kentucky University. A business occupancy we're working on has 550 occupants, and requires three means of egress per Section 7. Local jurisdictions may have previous (or newer) editions of NFPA 101 adopted. that would otherwise require means of egress to be kept unlocked. The building is protected throughout by an approved, supervised sprinkler system in accordance with NFPA 101-2012: 18/19. NFPA 101 Chapter 2, Referenced Publications requires 7. 2 Elevator lobby exit access door locking compliant with NFPA 101-2012: 7. The National Fire Protection Association (NFPA ®) standard NFPA 101®, Life Safety Code 2018, chapter 7 – Means of Egress, section 9 – Emergency Lighting requires emergency lighting to provide the following system performance:. The requirements below supersede the requirements of the NFPA 101: In buildings that are fully sprinklered, 1-hour fire rated corridors shall not be required. 2 states that automatic, motion sensor–type lighting switches shall be permitted within the means of egress, provided that the switch controllers are equipped for fail-safe operation, the illumination timers are set for a minimum 15-minute duration, and the motion sensor is activated by any occupant movement in the area. _____ 101 FR255 SAF-MEA (7. 9 for the following: (1) Buildings or structures where required in Chapters 11 through 43. 3 Each of these allowable exceptions are unique and have specific required features. A means of egress is comprised of exit access, exit, and exit discharge. NFPA 101 offers a flexible approach that adapts to new technologies, materials, and construction practices, innovations in design, and nontraditional uses of buildings. Chapter 7 According to NFPA 101, what is the minimum clear width of the opening for: Single Doors Pairs of Doors 32" At least one of the doors 32" List the three separate parts of the Means of Egress exit access exit exit discharge At what occupancy level is a door required to swing in the direction of egress? 50 Door and Hardware Institute. 1 states “Means of egress for both new and existing buildings shall comply with this chapter. Means of egress from dwelling units to the outside of the building are in accordance with Chapter 7, and the means of egress is continuously maintained free of all obstructions to full instant use in case of emergency. Allowable projections in accordance with Section 1003. include apartments, etc) as required in NFPA 101 Life Safety Code (2015 Edition) Chapter 24. Chapter 7 According to NFPA 101, what is the minimum clear width of the opening for: Single Doors Pairs of Doors 32" At least one of the doors 32" List the three separate parts of the Means of Egress exit access exit exit discharge At what occupancy level is a door required to swing in the direction of egress? 50 Door and Hardware Institute. 2; Locks are electrical and fail safe to release upon loss of power; The locks release by independent activation of each: Activation of the smoke detection system NFPA 101-2012: 18/19. ith the new edition of NFPA 101, Life Safety Code, the 2009 edition adds provisions to Chapter 7 for electrically controlled egress doors, horizontal-sliding doors, elevator lobby access door locking, and door inspection and maintenance. NFPA 101 part of the 2020 FFPC, 7 th edition Adopts With Amendments: NFPA 101, 2018 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5 Performance-Based Option Chapter 6 Classification of Occupancy and Hazard of Contents Chapter 7 Means of Egress 7. The 2021 edition provides the most current safety criteria with key revisions, including: Provisions making sprinklers mandatory in new daycare occupancies with more than 12 clients. The criteria of Chapter 7 was expanded to have applica-bility to all three portions of the means of egress: exit access, exit, and exit discharge. 1 indicates that egress shall be arranged such that each occupant has access to not less than two means of egress. Texas Administrative Code Next Rule>> (a) The provisions of NFPA 101, Chapter 7, Means of Egress, do not apply to a new small Type A assisted living facility, unless explicitly referenced by this section or by NFPA 101, Chapter 32, New Residential Board and Care Occupancies. NFPA 101 section 18/19. 1 Emergency lighting facilities for means of egress shall be provided in accordance with Section 7. The NFPA 101, Life Safety Code Handbook features complete Code text along with expert commentary that provides a narrative interpretation designed to make it easier to comprehend and apply provisions and explain technical language to nontechnical people. Changes other than editorial are indicated by a vertical rule beside the paragraph, table, or figure in which the change occurred. NFPA 101 offers a flexible approach that adapts to new technologies, materials, and construction practices, innovations in design, and nontraditional uses of buildings. Chapter 7: Means of Egress, Georgia Life Safety Code 2018 | UpCodes CODES Georgia Life Safety Code 2018 Adopts With Amendments: NFPA 101, 2018 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5 Performance-Based Option. Means of egress shall be continuously maintained free of all obstructions or impediments to full instant us e in the case of fire or other emergency. 2 Door openings in means of egress shall be not less than 32 in. ” NFPA 101 Chapters 7-11 all apply to both new and existing buildings, so you’ll need to review these chapters for specific existing building requirements that could apply to your situation. NFPA 101 CHAPTER 7 MEANS OF EGRESS FSE 101 – Fire Prevention Outline 2 General Requirements (Section 7. NFPA 101 section 18/19. Minimizing water accumulation for exterior stairs is required in. 2 Elevator lobby exit access door locking compliant with NFPA 101-2012: 7. Where approved by the authority having jurisdiction, outside stairs shall be permitted to lead to roofs of other sections of a building or an adjoining building where the construction is fire resistive and there is a continuous and safe means of egress from the roof. Components of a Means of Egress Required Means of Egress [IBC §1007. Chapter 7 According to NFPA 101, what is the minimum clear width of the opening for: Single Doors Pairs of Doors 32" At least one of the doors 32" List the three separate parts of the Means of Egress exit access exit exit discharge At what occupancy level is a door required to swing in the direction of egress? 50 Door and Hardware Institute. Chapter 7 Means of Egress 7. NFPA 101 The Life Safety Code, is the State adopted code for the protection of life in buildings. NFPA 101 part of the 2020 FFPC, 7 th edition Adopts With Amendments: NFPA 101, 2018 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5 Performance-Based Option Chapter 6 Classification of Occupancy and Hazard of Contents Chapter 7 Means of Egress 7. A business occupancy we're working on has 550 occupants, and requires three means of egress per Section 7. Minimizing water accumulation for exterior stairs is required in Section 7. A means of egress is an unobstructed path to leave buildings, structures, and spaces. NFPA 101 part of the 2020 FFPC, 7 th edition Adopts With Amendments: NFPA 101, 2018 Change Code Code Compare Chapter 1 Administration Chapter 2 Referenced Publications Chapter 3 Definitions Chapter 4 General Chapter 5 Performance-Based Option. Are all doors in a means of egress required to swing in the direction of egress travel?. Maine adopted the 2018 edition of NFPA 101 on November 1, 2019. 0 (1 review) A means of egress is composed of what 3 basics elements: Click the card to flip 👆. Upon completion, you should be able to: Explain classifications of occupancy, including NFPA 101 requirements relevant to new and existing buildings Reference provisions for components of the building's means of egress, fire alarm and suppression systems, and other fire protection features. Chapter 31 of the current edition covers existing apartment buildings. 8 Means of Egress General. 2) Access-controlled locking arrangements involve electronically locked doors that restrict egress. Components of Egress Exit Access-Portion of a means of egressthat leads to an exit Exit- Area separated from all other spacesby construction or equipment to protectway of travel to the discharge Exit Discharge-Area between thetermination of the Exit and the beginningof a public way. 8 Means of Egress. NFPA 101 Chapter 2, Referenced Publications requires 7. Headroom on stairs and stair landings shall be not less than 6 feet 8 inches (2030 mm) and shall be measured vertically above a plane parallel to, and tangent with, the most forward projection of the stair tread. 3 will allow doors not in a required means of egress to be locked in new and existing health care occupancies. Means of Egress: A continuous and unobstructed path of travel from any point in a building or structure to a public way that consists of the following three separate and distinct parts: Exit access: The travel path or area that leads from where a person is located to the entrance to an exit. For existing buildings, NFPA 101 §39. NFPA 101 has an extensive amount of information and requirements for stairs and stair enclosures. When the three means of egress are required per. When the three means of. Access-controlled egress door assemblies as defined in NFPA 101-2012: 7. 7 describes egress lighting systems and §39. 9 for the following: (1) Buildings or structures where required in Chapters 11 through 43 (2) Underground and limited access structures as addressed in Section 11. 2 for one- and two-family dwellings. (Where you have other than standard stairs such as curved stairs, spiral stairs or winders within a means of egress, consult NFPA 101, Life Safety Code, Chapter 7 for further details on their design. Means of egress shall be continuously maintained free of all obstructions or impediments to full instant us e in the case of fire or other emergency. Chapter 7 Means of Egress Chapter 8 Features of Fire Protection Chapter 9 Building Service and Fire Protection Equipment Chapter 10 Interior Finish, Contents, and Furnishings Chapter 11 Special Structures and High-Rise Buildings Chapter 12 New Assembly Occupancies Chapter 13 Existing Assembly Occupancies Chapter 14 New Educational Occupancies. 4 shall be provided at the open sides of means of egress that exceed 30 in. Any door assembly in a means of egress shall be of the side-hinged or pivoted-swinging type, and shall be installed to be capable of swinging from any position to the full required width of the opening in which it is installed, unless otherwise specified as follows: (1) Door assemblies in dwelling units, as provided in Chapter 24, shall be. The unlocking and unlatching operation from the egress side of the door shall be accomplished without the use of a key, tool, or special knowledge or effort. For example, NFPA 101 Section 7. Chapter 31 of the current edition covers existing apartment buildings. NFPA 101 offers a flexible approach that adapts to new technologies, materials, and construction practices, innovations in design, and nontraditional uses of buildings. Guards in accordance with 7. Statement: The provision proposed as 7.